Fluorine-18
F-18 · Fluorine, Z = 9, A = 18
Fluorine-18 (F-18) carries 3.52e+18 Bq/g, or 9.52e+7 Ci/g: a gigabecquerel is 284 pg, no weighable quantity at all. It decays by positron emission and some electron capture with a half-life of 109.77 minutes, which leaves 0.01% of today's activity after a day and 2.3e-26% after a week.
An air kerma rate constant of 0.135 mGy·m²/(GBq·h) is 1.7× Cs-137 and 2.3× less than Co-60, and 14 of 96 among the photon emitters carried here.
One line at 511.0 keV carries the whole of the dose rate.
Halving the air kerma rate calls for 3.90 mm of lead, or 10.6 mm of steel where lead is unwelcome, and a factor of ten calls for 13.0 mm of lead — sheet thicknesses that a glovebox or a transport container can carry. Reaching 20 µSv/h from 1 GBq at a metre takes 10.7 mm of lead.
F-18 as the working nuclide of positron emission tomography
F-18 is the radionuclide of most positron emission tomography (PET) studies, usually as fluorodeoxyglucose. It is produced in a cyclotron, incorporated into the tracer within hours and administered the same day; the decay table below shows why delivery schedules, patient throughput and staff rotas in a PET department are all built around its half-life.
Almost every decay ends in two annihilation photons emitted in opposite directions, which is what the scanner detects and also what makes a dosed patient a penetrating source. The shielding table reflects photons harder than those of most diagnostic nuclides: syringe shields are thick tungsten rather than thin lead, and the extremity dose to the technologist drawing the dose is the limiting quantity in many departments.
Waste decays to background overnight, so the handling problem is short-term external dose rather than disposal. The metre dose rate in the figures table is for a bare source; the rules for staff near a freshly injected patient start from it but use a lower figure, because the patient's own body absorbs part of the annihilation radiation.
The nuclide is made by proton bombardment of water enriched in O-18, and most departments receive it from a regional cyclotron rather than producing it on site. The activity ordered therefore includes the decay expected in transit, and a late delivery reduces the number of patients who can be scanned that day.
Among PET nuclides F-18 emits a positron of low energy, which travels only a short distance in tissue before it annihilates; that is part of why F-18 images are sharper than those made with Ga-68 or Rb-82. The penetrating annihilation photons are the price. Facility shielding is often designed with the method of the AAPM task group report on PET and PET/CT, and the uptake rooms where patients rest after injection often set the requirement, because that is where the patient sits with the most activity. Contamination is a lesser problem than with longer-lived tracers: a small spill can often be covered, cordoned off and left to decay for a day, which exposes fewer people than an immediate clean-up.
Half-life, specific activity and dose rate
| Half-life | 109.77 minutes (6586 s) |
| Decay mode | positron emission and some electron capture |
| Specific activity | 3.52e+18 Bq/g (9.52e+7 Ci/g) |
| Air kerma rate constant Γ (δ = 20 keV) | 0.135 mGy·m²/(GBq·h) |
| Dose rate, 1 GBq at 1 m | 0.135 mGy/h |
| Dose rate, 1 Ci at 1 m | 4.98 mGy/h |
| Kerma-weighted mean photon energy | 511.0 keV |
A single photon line at 511 keV
No recorded line for F-18 falls below the 20 keV cutoff, so this table is the whole photon spectrum. Probability and dose share.
| Energy (keV) | Emission probability (%) | Share of dose rate (%) |
|---|---|---|
| 511.00 | 193.46 | 100.00 |
3.90 mm of lead halves this spectrum
Solved for the single line, narrow beam. How the half-value layer is solved.
| Material | HVL (mm) | TVL (mm) | TVL / HVL |
|---|---|---|---|
| lead | 3.90 | 13.0 | 3.32 |
| tungsten | 2.68 | 8.90 | 3.32 |
| iron | 10.6 | 35.1 | 3.32 |
| copper | 9.35 | 31.1 | 3.32 |
| concrete | 34.1 | 113 | 3.32 |
| water | 72.2 | 240 | 3.32 |
| aluminum | 30.7 | 102 | 3.32 |
With one line the ratio is the single-energy 3.32. Spectrum and attenuation ratios.
Activity over the first hours
Ten half-lives is 18.3 hours, so the activity moves measurably while a count is running: every figure has to carry the time it was referred to. The mean life 1/λ is 2.64 hours.
| Elapsed | Fraction remaining |
|---|---|
| 1 half-life | 50.0 % |
| 2 half-lives | 25.0 % |
| 5 half-lives | 3.13 % |
| 10 half-lives | 0.0977 % |
| Time to fall to 10 % of today's activity | 6.08 hours |
| Time to fall to 1 % | 12.2 hours |
| Time to fall to 0.1 % | 18.2 hours |
Limits of these dose rates
- Air kerma, 1 µGy counted as 1 µSv — not H*(10).
- Model limits and internal dose.
Gamma and decay calculators for F-18
- Gamma dose rate and shielding
- Decay and half-life
- Mass and activity
- Detection limits (MDA / MDC)
- Remaining-activity table